Nawaf
All calculators

Qp/Qs

The pulmonary to systemic flow ratio from outflow tract diameters and VTIs, for ASD, VSD and PDA.

Doppler volumetric method

Shunt

For an ASD or VSD the pulmonary flow is measured at the RVOT. For a PDA the extra flow returns to the left heart, so the LVOT carries pulmonary flow.

Where is the shunt?

Left ventricular outflow
mm
cm
Right ventricular outflow

Measure the diameter at the same level as the PW sample volume.

mm
cm
Heart rate

Optional, for flows in L/min.

bpm
How it's calculated

Formula

Flow = π × (diameter ÷ 2)² × VTI, diameter in cm (mm ÷ 10) ASD or VSD: Qp/Qs = RVOT flow ÷ LVOT flow PDA: Qp/Qs = LVOT flow ÷ RVOT flow

Reading the ratio

The diameter is squared, so a 1 mm error changes the ratio by about 10%. Average several beats, and repeat the RVOT diameter in more than one view.

For education and as a reporting aid. A result supports the reading of the full study and does not replace it.